SSCIENCES Micropipette FAC Plus — Fixed and Variable Volume
The SSCIENCES FAC Plus Micropipette combines comfortable liquid
handling with complete steam sterilization. Its entire assembly
can be autoclaved at 121°C for 20 minutes without disassembly,
simplifying preparation for laboratory workflows that require
regular sterilization.
Lightweight construction and low-force plunger movement help
reduce hand fatigue during repeated pipetting. Variable-volume
models feature smooth volume adjustment and a click-stop mechanism
that helps prevent accidental setting changes. A streamlined
tip ejector, compatibility with most standard laboratory tips
and an individual calibration report support convenient
everyday operation.
Product Specifications
-
Brand and model:
SSCIENCES FAC Plus. -
Configurations:
Fixed-volume and variable-volume micropipettes. -
Full autoclavability:
Entire micropipette steam-autoclavable at 121°C for
20 minutes without disassembly. -
Ergonomic construction:
Lightweight design for comfortable, single-handed operation. -
Volume adjustment:
Smooth plunger rotation with click-stop control on
variable-volume models. -
Low-force plunger:
Stated operating force of 3–5 N for the first step
and 10–14 N for the second step. -
Two-step operation:
Supports reverse pipetting for applications such as
handling detergent solutions. -
Volume display:
Clear, protected display for convenient reading. -
Tip ejection:
Separate, streamlined ejector designed for access to
narrow-necked containers and tubes. -
Tip compatibility:
Compatible with most standard laboratory pipette tips. -
Construction material:
Durable, lightweight polypropylene as specified
in the product document. -
Calibration and maintenance:
Designed for convenient calibration and servicing;
supplied with an individual calibration report.
FAC Plus Variable-Volume Micropipettes
| Catalogue No. | Volume Range | Increment | Inaccuracy (%) | Imprecision (%) |
|---|---|---|---|---|
| FAC PLUS-V2 | 0.2–2 µL | 0.02 µL | ±0.2–2.0 | <0.5–2.0 |
| FAC PLUS-V10 | 0.5–10 µL | 0.1 µL | ±5.0–1.0 | <5.0–2.0 |
| FAC PLUS-V20 | Confirm range | 0.1 µL | ±4.0–2.0 | <2.0–0.8 |
| FAC PLUS-V50 | 5–50 µL | 1.0 µL | ±2.5–1.4 | <1.5–0.6 |
| FAC PLUS-V100 | 10–100 µL | 1.0 µL | ±2.0–1.5 | <1.0–0.6 |
| FAC PLUS-V200 | 20–200 µL | 1.0 µL | ±2.0–1.5 | <0.8–0.4 |
| FAC PLUS-V1000 | 100–1000 µL | 10.0 µL | ±1.5–1.2 | <0.6–0.4 |
| FAC PLUS-V5000 | 0.5–5 mL | 100.0 µL | ±5.0–0.5 | <0.6–0.4 |
| FAC PLUS-V10000 | 1–10 mL | 100.0 µL | ±1.5–0.5 | <0.6–0.5 |
FAC Plus Fixed-Volume Micropipettes
| Catalogue No. | Fixed Volume | Inaccuracy (%) | Imprecision (%) |
|---|---|---|---|
| FAC PLUS-F5 | 5 µL | ±2.5 | <1.5 |
| FAC PLUS-F10 | 10 µL | ±1.2 | <0.8 |
| FAC PLUS-F20 | 20 µL | ±1.0 | <0.4 |
| FAC PLUS-F25 | 25 µL | ±1.0 | <0.4 |
| FAC PLUS-F50 | 50 µL | ±0.8 | <0.3 |
| FAC PLUS-F100 | 100 µL | ±0.8 | <0.3 |
| FAC PLUS-F200 | 200 µL | ±0.8 | <0.3 |
| FAC PLUS-F250 | 250 µL | ±0.8 | <0.3 |
| FAC PLUS-F500 | 500 µL | ±0.8 | <0.3 |
| FAC PLUS-F1000 | 1000 µL | ±0.8 | <0.3 |
| FAC PLUS-F5000 | 5000 µL | ±0.8 | <0.3 |
| FAC PLUS-F10000 | 10000 µL | ±0.8 | <0.3 |